<?xml version="1.0" encoding="UTF-8"?>
<article article-type="research-article" dtd-version="1.3" xml:lang="ru" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:noNamespaceSchemaLocation="https://metafora.rcsi.science/xsd_files/journal3.xsd">
  <front>
    <journal-meta>
      <journal-id journal-id-type="publisher-id">moitvivt</journal-id>
      <journal-title-group>
        <journal-title xml:lang="ru">Моделирование, оптимизация и информационные технологии</journal-title>
        <trans-title-group xml:lang="en">
          <trans-title>Modeling, Optimization and Information Technology</trans-title>
        </trans-title-group>
      </journal-title-group>
      <issn pub-type="epub">2310-6018</issn>
      <publisher>
        <publisher-name>Издательство</publisher-name>
      </publisher>
    </journal-meta>
    <article-meta>
      <article-id pub-id-type="doi">10.26102/2310-6018/2022.36.1.018</article-id>
      <article-id pub-id-type="custom" custom-type="elpub">1135</article-id>
      <title-group>
        <article-title xml:lang="ru">Алгоритм определения пульса на фонокардиограмме человека и плода без классификации тонов сердца</article-title>
        <trans-title-group xml:lang="en">
          <trans-title>The algorithm for pulse measurement using a human’s and fetus’s phonocardiogram without classifying heart sounds</trans-title>
        </trans-title-group>
      </title-group>
      <contrib-group>
        <contrib contrib-type="author" corresp="yes">
          <contrib-id contrib-id-type="orcid">0000-0003-0775-350X</contrib-id>
          <name-alternatives>
            <name name-style="eastern" xml:lang="ru">
              <surname>Костелей</surname>
              <given-names>Яна Валерьевна</given-names>
            </name>
            <name name-style="western" xml:lang="en">
              <surname>Kosteley</surname>
              <given-names>Yana Valeryevna</given-names>
            </name>
          </name-alternatives>
          <email>kosteleyyv@gmail.com</email>
          <xref ref-type="aff">aff-1</xref>
        </contrib>
        <contrib contrib-type="author" corresp="yes">
          <contrib-id contrib-id-type="orcid">0000-0002-8639-0681</contrib-id>
          <name-alternatives>
            <name name-style="eastern" xml:lang="ru">
              <surname>Жданов</surname>
              <given-names>Дмитрий Сергеевич</given-names>
            </name>
            <name name-style="western" xml:lang="en">
              <surname>Zhdanov</surname>
              <given-names>Dmitriy Sergeevich</given-names>
            </name>
          </name-alternatives>
          <email>d_s_zhdanov@mail.ru</email>
          <xref ref-type="aff">aff-2</xref>
        </contrib>
        <contrib contrib-type="author" corresp="yes">
          <contrib-id contrib-id-type="orcid">0000-0003-2707-7203</contrib-id>
          <name-alternatives>
            <name name-style="eastern" xml:lang="ru">
              <surname>Боровской</surname>
              <given-names>Игорь Георгиевич</given-names>
            </name>
            <name name-style="western" xml:lang="en">
              <surname>Borovskoy</surname>
              <given-names>Igor Georgievich</given-names>
            </name>
          </name-alternatives>
          <email>igor.g.borovskoi@tusur.ru</email>
          <xref ref-type="aff">aff-3</xref>
        </contrib>
      </contrib-group>
      <aff-alternatives id="aff-1">
        <aff xml:lang="ru">Томский государственный университет систем управления и радиоэлектроники ООО «Диагностика +»</aff>
        <aff xml:lang="en">Tomsk State University of Control Systems and Radioelectronics Diagnostika + LLC</aff>
      </aff-alternatives>
      <aff-alternatives id="aff-2">
        <aff xml:lang="ru">ООО «Диагностика +» Томский государственный университет</aff>
        <aff xml:lang="en">Diagnostics + LLC Tomsk State University</aff>
      </aff-alternatives>
      <aff-alternatives id="aff-3">
        <aff xml:lang="ru">Томский государственный университет систем управления и радиоэлектроники, Томск</aff>
        <aff xml:lang="en">Tomsk State University of Control Systems and Radioelectronics</aff>
      </aff-alternatives>
      <pub-date pub-type="epub">
        <day>01</day>
        <month>01</month>
        <year>2026</year>
      </pub-date>
      <volume>1</volume>
      <issue>1</issue>
      <elocation-id>10.26102/2310-6018/2022.36.1.018</elocation-id>
      <permissions>
        <copyright-statement>Copyright © Авторы, 2026</copyright-statement>
        <copyright-year>2026</copyright-year>
        <license license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/">
          <license-p>This work is licensed under a Creative Commons Attribution 4.0 International License</license-p>
        </license>
      </permissions>
      <self-uri xlink:href="https://moitvivt.ru/ru/journal/article?id=1135"/>
      <abstract xml:lang="ru">
        <p>Актуальность работы обусловлена перспективами применения фонокардиограмм для проведения суточного мониторинга за состоянием плода и матери за счет конструирования недорогих портативных устройств. На данный момент отсутствуют программно-аппаратные комплексы, полностью решающие данную задачу. В связи с этим, в статье представлен алгоритм определения пульса на фонокардиограмме для обработки сигнала в потоковом режиме. Особенностью алгоритма является определение пульса человека или плода на основе сегментации звуков тонов сердца без проведения их классификации на первый и второй сердечный звук, а также в условиях присутствия иных физиологических и механических звуков, отсутствия одного из тонов сердца на сигнале и наличия отклонений границ сегментированных тонов от реальной локализации звуков сердечно-сосудистой системы. Для оценки достоверности результатов было произведено сравнение пульсовых значений, полученных разработанным алгоритмом и референтными методами. В качестве эталона для сравнения использовались значения пульса, полученные при обработке электрокардиограммы и рассчитанные двумя экспертами на основе фонокардиограммы. Среднее относительное отклонение между полученными результатами и результатами референтных методов не превышает 3 %. Материалы статьи представляют практическую ценность для конструирования систем суточного мониторинга состояния плода и человека.</p>
      </abstract>
      <trans-abstract xml:lang="en">
        <p>The relevance of the research is due to the prospects of phonocardiogram employment for daily monitoring of a fetus’s and mother’s state by designing inexpensive portable devices. Currently, there are no software and hardware systems that completely solve this problem. In this regard, the article presents the algorithm for pulse measurement by means of a phonocardiogram for signal processing in the streaming mode. The algorithm feature is a human’s and fetus’s pulse measurement based on the heart sound segmentation without classifying them into the first and second heart sounds, as well as detecting them under the conditions of other physiological and mechanical sounds, absence of one of the heart sounds in the signal, and deviations in the segmented sound boundaries from the actual localization of the cardiovascular system. For assessing the credibility of the results, the pulse values, obtained by the developed algorithm and reference methods, were compared. The pulse values, calculated by two experts with the aid of a phonocardiogram, were used as a standard for comparison. The average relative deviation between the findings and the reference method results does not exceed 3 %. The article materials are of practical value for the design of a fetus and human state daily monitoring systems.</p>
      </trans-abstract>
      <kwd-group xml:lang="ru">
        <kwd>фонокардиограмма</kwd>
        <kwd>кардиоинтервалограмма</kwd>
        <kwd>сегментация звуков тонов сердца</kwd>
        <kwd>частота сердечных сокращений</kwd>
        <kwd>обработка сигналов</kwd>
      </kwd-group>
      <kwd-group xml:lang="en">
        <kwd>phonocardiogram</kwd>
        <kwd>cardiointervalogram</kwd>
        <kwd>heart sound segmentation</kwd>
        <kwd>heart rate</kwd>
        <kwd>signal processing</kwd>
      </kwd-group>
      <funding-group>
        <funding-statement xml:lang="ru">Исследование выполнено без спонсорской поддержки.</funding-statement>
        <funding-statement xml:lang="en">The study was performed without external funding.</funding-statement>
      </funding-group>
    </article-meta>
  </front>
  <back>
    <ref-list>
      <title>References</title>
      <ref id="cit1">
        <label>1</label>
        <mixed-citation xml:lang="ru">Здравоохранение в России. 2019. стат. сб. М.: Росстат; 2019. 170 с.</mixed-citation>
      </ref>
      <ref id="cit2">
        <label>2</label>
        <mixed-citation xml:lang="ru">Kovacs F., Torok M., Habermajer I. A rule-based phonocardiographic method for long-term fetal heart rate monitoring. IEEE Transactions on Biomedical Engineering. 2000;47(1):124–130. DOI: 10.1109/10.817627.</mixed-citation>
      </ref>
      <ref id="cit3">
        <label>3</label>
        <mixed-citation xml:lang="ru">Liu C., Springer D., Li Q., Moody B., Juan R.A., Chorro F.J., Clifford G.D. An open access database for the evaluation of heart sound algorithms. Physiological Measurement. 2016;37(12):2181–2213. DOI: 10.1088/0967-3334/37/12/2181.</mixed-citation>
      </ref>
      <ref id="cit4">
        <label>4</label>
        <mixed-citation xml:lang="ru">Chetlur Adithya P., Sankar R., Moreno W.A., Hart S. Trends in fetal monitoring through phonocardiography: Challenges and future directions. Biomedical Signal Processing and Control. 2017;33:289–305. DOI: 10.1016/j.bspc.2016.11.007.</mixed-citation>
      </ref>
      <ref id="cit5">
        <label>5</label>
        <mixed-citation xml:lang="ru">El-Segaier M., Lilja O., Lukkarinen S., Sörnmo L., Sepponen R., Pesonen E. Computer-Based Detection and Analysis of Heart Sound and Murmur. Annals of Biomedical Engineering. 2005;33(7):937–942. DOI: 10.1007/s10439-005-4053-3.</mixed-citation>
      </ref>
      <ref id="cit6">
        <label>6</label>
        <mixed-citation xml:lang="ru">Tang H., Li T., Qiu T., Park Y. Fetal Heart Rate Monitoring from Phonocardiograph Signal Using Repetition Frequency of Heart Sounds. Journal of Electrical and Computer Engineering. 2016:1–6. DOI: 10.1155/2016/2404267.</mixed-citation>
      </ref>
      <ref id="cit7">
        <label>7</label>
        <mixed-citation xml:lang="ru">Nivitha Varghees V., Ramachandran K.I., Soman K.P. Wavelet-based fundamental heart sound recognition method using morphological and interval features. Healthcare Technology Letters. 2018;5(3):81–87. DOI: 10.1049/htl.2016.0109.</mixed-citation>
      </ref>
      <ref id="cit8">
        <label>8</label>
        <mixed-citation xml:lang="ru">Твардовский В.И., Дмитрачков В.В., Былинский Н.Н., Волкова О.Н., Каледа А.Г., Назаренко О.Н., Самохвал О.В. Основы электрокардиографии детского возраста. Учеб.-метод. пособие. Минск: БГМУ; 2011. 76 с.</mixed-citation>
      </ref>
      <ref id="cit9">
        <label>9</label>
        <mixed-citation xml:lang="ru">Аед В.М., Исаков Р.В., Сушкова Л.Т., Аль-Хайдри В.А. Алгоритм построения кардиоинтервалограммы на основе фонокардиограммы. Радиотехнические и телекоммуникационные системы. 2016;22(2):34–43.</mixed-citation>
      </ref>
      <ref id="cit10">
        <label>10</label>
        <mixed-citation xml:lang="ru">International Standard. ISO 5840-2:2015 (E): Cardiovascular implants: cardiac valve prostheses. Part 2: Surgically implanted heart valve substitutes; 2015. Режим доступа: https://www.iso.org/standard/51314.html (дата обращения: 1.12.2021).</mixed-citation>
      </ref>
      <ref id="cit11">
        <label>11</label>
        <mixed-citation xml:lang="ru">Chung C.S., Karamanoglu M., Kovács S.J. Duration of diastole and its phases as a function of heart rate during supine bicycle exercise. American Journal of Physiology-Heart and Circulatory Physiology. 2004;287(5):H2003–H2008. DOI: 10.1152/ajpheart.00404.200.</mixed-citation>
      </ref>
      <ref id="cit12">
        <label>12</label>
        <mixed-citation xml:lang="ru">Yuenyong S., Nishihara A., Kongprawechnon W., Tungpimolrut K. A framework for automatic heart sound analysis without segmentation. BioMedical Engineering OnLine, 2011;10(1):13. DOI:10.1186/1475-925x-10-13.</mixed-citation>
      </ref>
      <ref id="cit13">
        <label>13</label>
        <mixed-citation xml:lang="ru">Костелей Я.В., Жданов Д.С., Боровской И.Г. Адаптация фильтра нелокального усреднения для усиления звуков тонов сердца на фонокардиограммах плода и человека. Вестник СибГУТИ. 2021;3:77–91.</mixed-citation>
      </ref>
      <ref id="cit14">
        <label>14</label>
        <mixed-citation xml:lang="ru">Шаргаева Н.В. Диагностика угрожаемых состояний плода во время беременности и в родах. Проблемы здоровья и экологии. 2005;3:103–112.</mixed-citation>
      </ref>
      <ref id="cit15">
        <label>15</label>
        <mixed-citation xml:lang="ru">Dares G.S., Houghton C.R.S., Redman C.W.G. Baseline in human fetal heart-rate records. BJOG: An International Journal of Obstetrics and Gynaecology. 1982;89(4):270–275. DOI: 10.1111/j.1471-0528.1982.tb04695.x.</mixed-citation>
      </ref>
      <ref id="cit16">
        <label>16</label>
        <mixed-citation xml:lang="ru">Kazemnejad A., Gordany P., Sameni R. An open-access simultaneous electrocardiogram and phonocardiogram database. BioRxiv. 2021. Режим доступа: DOI: 10.1101/2021.05.17.444563 (дата обращения: 1.12.2021).</mixed-citation>
      </ref>
    </ref-list>
    <fn-group>
      <fn fn-type="conflict">
        <p>The authors declare that there are no conflicts of interest present.</p>
      </fn>
    </fn-group>
  </back>